Predictive Maintenance with Oil Moisture Measurement


Moisture is a known contaminant in a wide variety of applications and processes, but the presence of moisture in industrial use oil can be particularly detrimental. Affecting the quality and performance of the oil, water is known to increase viscosity and cavitation. It also degrades additives and film strength and presents the opportunity for biological contamination and corrosion.

Counter to the old adage, "oil and water do mix," water can coexist with oil in three forms: dissolved, emulsified, and free water. Dissolved water is a natural condition, where individual water molecules are diffused in the oil, much like how we recognize water molecules as humidity in the air. Emulsified and free water are conditions where the oil has become saturated, causing the water to be suspended and separated in the oil. These latter forms present the most harmful conditions and maintenance challenges to hydraulic, lubrication and other industrial systems.

Industrial oils differ in many ways, as do the acceptable levels of absolute moisture in them. Every oil begins with a base stock and then varies based on the additives used to provide different physical and chemical properties. With use, oils age and their condition degrades, contaminants are introduced, and they can begin to oxidize. This allows the oil to hold more water in the dissolved state, varying its saturation point. This variation is important, as it affects which measurement parameters are most relevant for preventative maintenance. Conventional parts per million (ppm) measures become less relevant as oils age, so Vaisala has standardized on the water activity (aw) and percent of relative saturation (%RS) parameters to indicate relevant dissolved moisture levels. The aw and %RS parameters are independent of oil type and account for fluctuating temperatures and saturation points, thus providing a more useful measurement for preventative maintenance.

Knowing the concentration of dissolved water relative to the oil’s saturation point is the best indicator to predict when the oil and water will begin to separate. This information can be used to detect water ingress problems, trigger maintenance events and oil replacement intervals.

Detecting the dangerous accumulation of water in oil begins with reliable and accurate measurement, and there are different methods for measuring the dissolved water in oil. Traditional methods involve sampling and analysis, but only direct inline measurement with a capacitive polymer sensor offers real-time information. These inline measurements provide continuous data that can be acted upon quickly to prevent harmful conditions. Access to this information provides a measurable return on investment with energy savings, preventative maintenance scheduling and fault indication.

Vaisala uses our own HUMICAP® sensor technology for measuring moisture in oil, and the HUMICAP® sensors were the very first that could measure moisture in oil online. The sensor materials are specifically developed to measure very low moisture levels in hydrocarbons, and the measurement also considers the temperature of the oil. With almost 50 years of experience developing and manufacturing capacitive moisture sensors for air and oil, Vaisala has become the market leader for this application across multiple industries including lubrication systems, maritime and the paper industry. Built in our own cleanrooms, these sensors offer long-term stable and precise measurements that you can trust, no matter how robust the application.

Moisture removal is another key component to oil maintenance, and common methods for high-quality oils include vacuum dehydration and different forms of filtration with a water absorbing media. Online drying delivers a rapid improvement in oil quality, but this improvement may not be permanent. Subsequent monitoring is prudent and can often result in another drying cycle. Effective on-line drying requires a sustained effort and consistent moisture measurement for quality control, which sampling cannot match.

Vaisala offers its HUMICAP® technology in a number of flexible installation and integration options. From portable meters and smart probes, to advanced transmitters and OEM solutions, Vaisala Moisture in Oil instruments are designed to protect your capital equipment investment.


Vaisala_Logo_Blue_RGB
Vaisala GmbH
Rheinwerkallee 2
53227 Bonn
Germany
Phone: +49 228 249710
Fax: +49 228 2497111
email: vertrieb@vaisala.com
Internet: http://www.vaisala.de

Company profile show

Contacts show

Reinraum-Shop show

Publications: Further publications by this company / author

Other articles under these categories: Monitoring & Measurement: Humidity


Better informed: With YEARBOOK, NEWSLETTER, NEWSFLASH and EXPERT DIRECTORY

Stay up to date and subscribe to our monthly eMail-NEWSLETTER and our NEWSFLASH. Get additional information about what is happening in the world of cleanrooms with our printed YEARBOOK. And find out who the cleanroom EXPERTS are with our directory.

Vaisala Buchta Systec & Solutions GmbH ClearClean