Here you can find the NEWSLETTER archive More ...
HJM PMS Ecolab Buchta

cleanroom online
Deutsch   English



Gx® InnoSafeTM

Customized for manufacturers and users

Gx® InnoSafeTM – ein integriertes, passives Sicherheitssystem zur Vermeidung von Nadelstichverletzungen. / Gx® InnoSafeTM - integrated passiv safety system for the prevention of needlestick injuries.
Gx® InnoSafeTM – ein integriertes, passives Sicherheitssystem zur Vermeidung von Nadelstichverletzungen. / Gx® InnoSafeTM - integrated passiv safety system for the prevention of needlestick injuries.
Die Spritzen werden einschließlich Sicherheitsverschluss in Lochtrays und Standardwanne verpackt und mit Ethylenoxidgas sterilisiert. Sie können auf bestehenden Abfülllinien ohne zusätzliche Vorbereitungs- und Assemblierungsschritte verarbeitet werden. / The syringes, including the safety system, are packed in perforated trays and tubs and then sterilized with ethylene oxide gas. They can be processed on existing filling lines without additional preparation and assembly steps.
Die Spritzen werden einschließlich Sicherheitsverschluss in Lochtrays und Standardwanne verpackt und mit Ethylenoxidgas sterilisiert. Sie können auf bestehenden Abfülllinien ohne zusätzliche Vorbereitungs- und Assemblierungsschritte verarbeitet werden. / The syringes, including the safety system, are packed in perforated trays and tubs and then sterilized with ethylene oxide gas. They can be processed on existing filling lines without additional preparation and assembly steps.

With their exposed cannulas, used syringes are an omnipresent source of danger in medical practices, labs, or hospitals. Existing needle protection systems reduce the risk of injury for the user, but require additional effort for filling on the part of the pharmaceutical companies and with respect to the use of the syringe by medical personnel. With Gx InnoSafe, Gerresheimer introduces a syringe with an integrated safety system for the avoidance of needlestick injuries that fulfils the current requirements of the pharmaceuticals industry and of users equally.

One careless movement is enough for medical specialists to injure themselves on unprotected, used syringe cannulas or come into contact with aggressive active ingredients. In the most adverse case, this can result in serious infections. There is also a danger that already used syringes may accidentally be used a second time. Gx InnoSafe provides reliable protection against needlestick injuries and eliminates the possibility of reuse. In contrast with many existing solutions, the needle protection mechanism is thereby activated automatically and requires no additional actions. This thus involves a so-called passive needle protection system. Also of advantage to the pharmacists is the processing of the Gx InnoSafe syringes, which can take place on existing lines in the nested state without significant changes. An additional installation step of a safety system, as is usual on the market, is dispensed with.

The user wishes a safety system that leaves the familiar injection procedure unchanged, is intuitive and can be operated ergonomically, and which requires no additional manual activation to secure the cannula prior to disposal. The Gx InnoSafe safety system is installed like a standard seal in the clean room on Gx RTF glass syringes in the context of the manufacturing process. The syringe body itself remains completely visible, so that the presence, filling level, and state of the active ingredient, as well as the injection procedure can be inspected without obstacles. The injection itself is administered as usual. Following the removal of the ergonomically optimized sealing cap with the integrated flexible needle shield, the syringe is positioned at the injection point, the cannula inserted into the tissue to be administered and the active ingredient injected as with a conventional syringe. An accidental triggering of the safety system isn't possible, as the mechanism is completely relaxed prior to the injection. The system is first activated with the pricking of the cannula and then automatically ensures when removing the syringe from the injection point that the safety mechanism is permanently locked. In this way, the cannula is reliably covered and renewed use of the syringes is impossible.

For the pharmaceuticals company, Gx InnoSafe offers advantages for the filling process of ready-to-fill syringes. The safety system is positioned fully automatically in the RTF process and visually inspected with an X-ray check to 100 percent for correct positioning. The syringes, including the safety system, are packed in perforated trays and tubs and then sterilized with ethylene oxide gas. They can be processed on existing filling lines without additional preparation and assembly steps. Here too, the design of the safety mechanism ensures that unintended activation while filling, packaging, and transport is avoided. With the introduction of the new product line, Gx InnoSafe is available for the 1.0 ml long RTF glass syringe with a ½“ cannula. Additional syringe variants will follow.


Gerresheimer AG
40468 Düsseldorf
Germany


Better informed: With YEARBOOK, NEWSLETTER, NEWSFLASH and EXPERT DIRECTORY

Stay up to date and subscribe to our monthly eMail-NEWSLETTER and our NEWSFLASH. Get additional information about what is happening in the world of cleanrooms with our printed YEARBOOK. And find out who the cleanroom EXPERTS are with our directory.

ClearClean Vaisala Hydroflex C-Tec