SCHMIDT Strömungssensor SS 20.415 zur LF-Überwachung
SCHMIDT® flow sensor SS 20,415 novelty the new SCHMIDT flow sensor SS
20,415 is a special sensor for laminar flow monitoring in
clean-spacetechnical plants. It concerns a rod-shaped flow probe on
basis of a thermal anemometer, which can measure both the flow rate
and direction of flow of air and gases. The thin feeler pipe made of
high-grade steel also highly integrated electronics on microprocessor
basis accommodates only 9 mm beside the sensor element. The sensor is
developed, the measuring element by an aerodynamic flow chamber from
mechanical load is protected reliably durably. Additionally to the
analogue output the sensor has a direction as well as a threshold
value exit. The SS 20,415 has the desired SCHMIDT pure space rapid
assembly system. Behind it a high-grade steel mounting adaptor hides
itself, to that alternatively into the wall or built into the cover.The sensor is screwed in into this mounting adaptor and has then
automatically the correct position into purchase to the filter cover.
Schmidt supplies this mounting adaptor to different variants, suitably
all usual pure space floor schemes. Making handforged supporting
device belongs thereby finally to history. Removement or replacement
of the sensor takes only seconds, the disassembly of separate
electronics together with wiring is void with this sensor. That
perfectly closed developed sensor may be sterilized in the enterprise
with alcohols and hydrogen peroxide. Conspicuous it is also that the
sensor can measure already very small currents starting from 0,05 m/s.
When desired the sensor with a restorable calibration certificate is
supplied. Areas of application laminar flow monitoring in pure areas
for Pharmaproduktion, fine chemistry, semiconductor industry, optical
industry and food industry.To the installation under filter covers, flow boxes and in insulators.
Technical data design: Rod-shaped flow probe in straight lines or bent
execution, transducer in the feeler pipe integrates. Measurement
principle: Thermal anemometer area of application: Freely flowing air
of measuring range: 1 or 2.5 m/s measuring range beginning: 0.05 m/s
response time: adjustable 10 ms to 10 s (T90) assembly: Rapid assembly
system with 5 different mounting adaptors suitably for marketable
floor schemes, installation alternatively in wall or cover supply:
12... 24 VDC power input: under 10 mA of exits: 0..2 V/0..5 V/0..10
V/0..20 mA/4..20 mA plus 2 open Collector of exits for direction and
threshold value, R-S 232 to the Parametrierung.Shockproof sterilization bar in the enterprise does not pack
product advantages SCHMIDT pure space rapid assembly system for very
fast installation and removal very stable building method, sensor
element in the chamber head by alcohols or H2O2 readjusting in the
field by drift-stable semiconductor sensor element detection of the
back flow electronics in the feeler pipe integrated = smallest one
costs with the installation manufacturer SCHMIDT Technology GmbH,
Feldbergstr. 1, 78112 St. Georgen, Tel.:Â +49/7724/899-0
Fax:+49/7724/899101, email: info@schmidttechnology.de, homepage:
www.schmidttechnology.de
Better informed: With YEARBOOK, NEWSLETTER, NEWSFLASH and EXPERT DIRECTORY
Stay up to date and subscribe to our monthly eMail-NEWSLETTER and our NEWSFLASH. Get additional information about what is happening in the world of cleanrooms with our printed YEARBOOK. And find out who the cleanroom EXPERTS are with our directory.