Here you can find the NEWSLETTER archive More ...
ClearClean Becker Vaisala MT-Messtechnik

cleanroom online
Deutsch   English


  • Buildings & Rooms

Control and control in pure space production � security by clarity

Kontrolle und Steuerung in der Reinraumproduktion – Sicherheit durch Übersichtlichkeit
Kontrolle und Steuerung in der Reinraumproduktion – Sicherheit durch Übersichtlichkeit
Production in pure areas presupposes a high discipline and care within the range of the operational sequences. Product security had highest priority and the legally prescribed safety standards strengstens to be kept. GMP guidelines specify the parameters for particle and germ load, also to pressure, humidity and temperature must are kept constant and besides completely documented. Basic condition in the enterprise of a clean-room system is from there an exact attitude and vote of all components, constant control and recording of the values and first of all an immediate announcement and recovery of St�rungen.Die regulation and monitoring of a complex clean-room system with separate control devices for individual components such as pure area, laminar flow modules, air condition technology, air-lock doors or lighting required often the use of trained technicians. The responsible persons coworkers must dedicate a large temporal expenditure to the control and ensure the monitoring continuous. Even small inadvertence can lead to a contamination of the delicate products and cause serious consequences. Thus for example an inadvertently not closed door within the air-lock range leads to a decrease of pressure of the system, the flow conditions is no more ensured and the particle concentration rises. If a malfunctioning is noticed too late, this can lead to a production stop, which causes perhaps high costs. An ideal conception is therefore the installation of a clean-room system, which makes the high control responsibility as simple as possible and a simple, error free basic adjustment and control makes possible. With the advancement of its patented system SCHILLING CleanRoom control system CR control succeeded to the pure space specialist SCHILLING ENGINEERING GmbH now � a large step to the simplification of the regulation, control and monitoring and thus for the increased safety and productivity in pure areas. The 15 tariff large Touchscreen, which surface-concisely into the wall panel beside the entrance door one integrates, proves as multi-function equipment, that the complex operational sequence of the clean-room technology, of the air condition technology and the monitoring in equipment united and surely and intuitively to serve is: � control system describes a small part of the functions, which the CR control system carries out in the reason only. It is an interactive regulation, control and a monitor, which represent completely new in this form somewhat. The Touchscreen does not only indicate clearly and understandably the parameters, the individual functions can be headed for also immediately and adjusted � reports the electrical planner to Dietmar Schmitt, which was considerably in the development of the control system involved with Schilling engineering, not without Stolz.Die measurement effected with feelers, which are connected to pressure, dampness and temperature to supervise and by interfaces with the control system Simatic S7. The high-quality CONTROLLER of Siemens is programmed with a special software, which manufactures the necessary connections to the attached feelers, pure space modules, climatic cabinets and further components. So the values of up to 10 pure areas and 60 laminar flow modules can on a monitor be represented at the same time and the being comfortably be adjusted. A constant examination of the degree of pollution and the achievement of all assigned filters is important, in order to plan promptly a change and exclude loss losses. A characteristic of the again-developed system exists in the singular possibility of being able to select even those directly and clearly so far very complicated and separated steered air condition technology. Besides will the door control supervised and also the light function can comfortably be adjusted. The different features are selected over an intuitive prompting simply and are on different levels password secured and in such a way against abusive operation protected. Managing director G�nther Schilling sprays proper enthusiasm, if he speaks about the new development: � we attached particular importance on a directly understandable prompting. Procedures, with which an immediate interference is necessary, are made with a red color clearly visibly or release a warning clay/tone. The entire control and monitoring can be made uncomplicatedly directly by 15 tariff display. That is a giant progress. The customers can react fast and surely and concentrate on the actual process cycle. � SCHILLING the CleanRoom control system CR control � is already used into 6 tariff version since 2010 for the controlling of the clean-room systems by SCHILLING ENGINEERING. Starting from August 2011 15 tariff monitor the advancement, which ensures additionally the controlling of the air condition technology in an integrated way and a still larger clarity, stands to Verf�gung.Der 15 tariff Touchscreen SCHILLING of the CleanRoom control system CR control � makes possible clear control and regulation of all individual pure space components with that

This text was translated automatically.


Schilling_Logo_300dpi_rgb
Schilling Engineering GmbH
Industriestraße 26
79793 Wutöschingen
Germany
Phone: +49 7746 927890
email: info@schillingengineering.de
Internet: http://www.schillingengineering.de

Company profile show

Contacts show

Publications: Further publications by this company / author

Other articles under these categories: Buildings & Rooms Buildings & Rooms: Planning Buildings & Rooms: Facilities Buildings & Rooms: Doors Buildings & Rooms: Ceilings Buildings & Rooms: Walls Buildings & Rooms: Floor Buildings & Rooms: Light Buildings & Rooms: Assembly Buildings & Rooms: Turnkey Buildings & Rooms: Modular rooms, Cabins Buildings & Rooms: Minienvironment Buildings & Rooms: Sauberraum Building technology Building technology: Air Building technology: Air conditioning Building technology: Filter Furnishing & equipment Furnishing & equipment: Pass-through Furnishing & equipment: Flow box Furnishing & equipment: Sit-over Furnishing & equipment: Furniture Room, work & office material: Mats Monitoring & Measurement: Applications Monitoring & Measurement: Particles Clothing & Consumables Clothing & Consumables: Overall Clothing & Consumables: Gloves Clothing & Consumables: Bonnets Clothing & Consumables: Shoes, Boots, Overcoats Clothing & Consumables: Accessories Hygiene & Cleaning: Disinfection | procedures, devices, agents, media (Wipers, Swaps,...) Hygiene & Cleaning: Cleaning | procedures, devices, agents, media (Wipers, Swaps,...) Service Service: Consulting Service: GMP Service: Measurement Service: Laminar Flow Service: Maintenance Commissioning: Qualification Commissioning: Certification Production & Procedure Production & Procedure: Workbench Production & Procedure: Automation Production & Procedure: Robot Production & Procedure: Transfer systems Production & Procedure: Packaging Knowledge & Events: Training, Education


Better informed: With YEARBOOK, NEWSLETTER, NEWSFLASH and EXPERT DIRECTORY

Stay up to date and subscribe to our monthly eMail-NEWSLETTER and our NEWSFLASH. Get additional information about what is happening in the world of cleanrooms with our printed YEARBOOK. And find out who the cleanroom EXPERTS are with our directory.

Ecolab Systec & Solutions GmbH PMS HJM